Evaluation of MALDI-TOF MS for identification of nontuberculous mycobacteria isolated from clinical specimens in mycobacteria growth indicator tube medium

Küçük Resim Yok

Tarih

2018

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

EDIZIONI INT SRL

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

Nowadays, there is a rising worldwide incidence of diseases caused by nontuberculous mycobacteria (NTM) species, especially in immunocompromised patients and those with underlying chronic pulmonary diseases. Recently, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) became a method of choice for the identification of NTM species. The aim of this study was to evaluate MALDI-TOF MS for the identification of NTM isolates compared to the PCR-restriction enzyme analysis (PRA)-hsp65 method. In this study; a total of 152 NTM strains isolated from various clinical specimens were retrospectively analysed. MALDI-TOF MS successfully identified 148 (97.4%) of the 152 NTM isolates but failed to identify four (2.6%) of them. Bruker mycobacteria library gave spectral scores higher than 2.0 for 45 (29.6%) of NTM isolates, between 1.6 and 2.0 for 98 (64.5%) of NTM isolates, and lower than 1.6 for nine (5.9%) NTM isolates. The discordant results between MALDI-TOF MS and PRA-hsp65 analysis were confirmed by sequence analysis. In conclusion, MALDI-TOF MS is a technique capable of performing accurate, rapid, cost-effective, and easy identification of NTM isolates.

Açıklama

Anahtar Kelimeler

Nontuberculous mycobacteria, MALDI-TOF MS, Identification, PRA-hsp65

Kaynak

NEW MICROBIOLOGICA

WoS Q Değeri

Q4

Scopus Q Değeri

Q3

Cilt

41

Sayı

3

Künye