The experimental use of N-Butyl cyanoacrylate tissue adhesive in pulmonary wedge resections

dc.authorid0000-0001-9169-560Xen_US
dc.contributor.authorKoşar, Altuğ
dc.contributor.authorKapıcıbaşı, Oğuz
dc.contributor.authorAlpay, Levent
dc.contributor.authorMısırlıoğlu, Aysun K.
dc.contributor.authorSönmez, Hakan
dc.contributor.authorİskender, İlker
dc.contributor.authorDemirhan, Recep
dc.date.accessioned2024-07-12T21:04:02Z
dc.date.available2024-07-12T21:04:02Z
dc.date.issued2012en_US
dc.departmentFakülteler, Tıp Fakültesien_US
dc.description.abstractBackground: In this experimental study, the effectiveness of N-butyl cyanoacrylate tissue adhesive on preventing air leakage after pulmonary wedge resection was observed. Methods: Twenty pairs of sheep lungs were used. Before initiating the study, the sheep lungs were ventilated to identify any air leakage from the parenchyma. On positive results, those sheep lungs were then excluded from the study. Wedge resection was performed on the right and left lower lobes of sheep lungs by clamping the edges forming a triangle of 5 cm × 5 cm × 5 cm. One side of parenchyma was sutured by 3/0 vicryl (Group A) while the other side of parenchyma was sealed by N-butyl cyanoacrylate (Group B). After waiting for 5 min for N-butyl cyanoacrylate to dry, the sheep lungs were intubated by 6 F endotracheal tubes. The lungs were soaked in a bath tub filled with 10 cm deep water and inflated by 40 mmHg pressure to record any air leakage from the parenchyma partially sutured by vicryl and sealed by N-butyl cyanoacrylate. Results: Air leakages were observed on the parenchyma surfaces of group of lungs (100%) sutured by vicryl (minimal 30%, mild 50% or massive 20% levels), while only on four of (20%) the other group of lungs sealed by N-butyl cyanoacrylate,minimal airleakage was observedontheparenchymal surface.There was anextremely significantdifferencebetween Group A and Group B in terms of the development of air leakage (p = 000). Conclusion: We consider that, N-butyl cyanoacrylate could be used effectively and safely to prevent air leakage from the pulmonary wedge resection surface.en_US
dc.identifier.citationKapıcıbaşı, H. O., Alpay, L., Mısırlıoğlu, A. K., Sönmez, H., İskender, I. ve Demirhan, R. (2012). The experimental use of N-Butyl Cyanoacrylate tissue adhesive in pulmonary wedge resection. Heart Lung and Circulation. 21, s. 711-714.en_US
dc.identifier.endpage714en_US
dc.identifier.issue21en_US
dc.identifier.startpage711en_US
dc.identifier.urihttps://www.heartlungcirc.org/article/S1443-9506(12)01115-8/abstract
dc.identifier.urihttps://hdl.handle.net/20.500.12415/3745
dc.institutionauthorKoşar, Altuğ
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofHeart Lung and Circulationen_US
dc.relation.isversionof10.1016/j.hlc.2012.06.020en_US
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKY01177
dc.subjectN-Butyl cyanoacrylateen_US
dc.subjectPulmonary wedge resectionsen_US
dc.subjectSurgeryen_US
dc.subjectTissue adhesivesen_US
dc.titleThe experimental use of N-Butyl cyanoacrylate tissue adhesive in pulmonary wedge resectionsen_US
dc.typeArticle
dspace.entity.typePublication

Dosyalar