Yazar "Uludag, Mehmet" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Yayın Aberrant breast cancer(BLACKWELL PUBLISHING, 2007) Kebudi, Abut; Manukyan, Manuk Norayık; Uludag, Mehmet; Erdernir, Ayhan; Citgez, Buelent; Severge, Utku…Yayın CONTRIBUTION OF GAMMA PROBE-GUIDED SURGERY TO LATERAL APPROACH COMPLETION THYROIDECTOMY(AMER ASSOC CLIN ENDOCRINOL, 2009) Uludag, Mehmet; Yetkin, Gurkan; Citgez, Bulent; Isgor, Adnan; Atay, Murat; Kebudi, Abut; Akgun, IsmailObjective: To evaluate the effectiveness of gamma probe performed with technetium Tc 99m-labeled pertechnetate in patients who underwent completion thyroidectomy after pathologic detection of incidental thyroid cancer following subtotal thyroidectomy. Methods: In this prospective study, we evaluated findings from patients with multinodular goiter who underwent gamma probe-guided lateral approach completion thyroidectomy after the pathologic detection of incidental thyroid cancer following subtotal thyroidectomy where partial thyroid tissue was left unilaterally or bilaterally. Patients who underwent the procedure between January 2003 and January 2007 were included. Thyroid scintigraphy; thyroid and neck ultrasonography examinations; and concentrations of thyroid hormones, thyrotropin (TSH), thyroglobulin, and thyroglobulin antibodies were evaluated before the second operation. Patients were administered 3 mCi technetium Tc 99m pertechnetate during anaesthetic induction, and we extracted suspicious thyroid tissue and tissue with activity above background activity levels according to gamma probe. Extracted tissues were evaluated pathologically. Results: Completion thyroidectomy was performed in 23 patients. Seventy-nine tissue samples were extracted; 49 were thyroid tissue and 30 were nonthyroid tissue. Mean thyroid tissue to background activity ratio (T:B) was 6.4 +/- 3.9 (range, 2-14.3), and mean thyroid bed (after excision) to background activity ratio (Tbed:B) was 1.2 +/- 0.2 (range, 0.8-1.7) (P = .001). Mean T:13 and Tbed:B ratios of the nonthyroid tissue were 1.2 +/- 0.3 (range, 0.2-1.7) and 1.1 +/- 0.2 (range, 0.4-1.4), respectively (P = .001). The thyroid tissue T:B ratio was significantly higher than that of nonthyroid tissue (P <.001). Gamma probe labeling contributed to extraction of small amounts of thyroid tissue that could not be viewed by scintigraphy in 43% of patients. Conclusions: Using gamma labeling, thyroid tissue shows significantly more activity than nonthyroid tissue. Gamma probe helps detect small, residual thyroid tissue that is buried in the scar tissue that cannot be distinguished by scintigraphy; therefore, it assists in the extraction of the maximum amount of thyroid tissue. (Endocr Pract. 2009;15:213-219)Yayın Supernumerary ectopic parathyroid glands. Persistent hyperparathyroidism due to mediastinal parathyroid adenoma localized by preoperative single photon emission computed tomography and intraoperative gamma probe application(HELLENIC ENDOCRINE SOC, 2009) Uludag, Mehmet; Isgor, Adnan; Yetkin, Guerkan; Atay, Murat; Kebudi, Abut; Akgun, IsmailEctopic and/or supernumerary parathyroid glands are a major cause of persistent and recurrent Hyperparathyroidism (HPT). For this reason, it is widely accepted that preoperative localization should be performed to improve the surgical results in patients with persistent or recurrent HPT. Primary HPT (pHPT) was diagnosed incidentally in a 50-year old female patient during a preoperative examination for hernia. No pathologic parathyroid gland was detected in the preoperative Tc-99m Methoxybutylisonitrile (MIBI) scintigraphy and Ultrasonography (US). Cervical exploration was performed bilaterally. Four parathyroid glands were located adjacent to the thyroid gland. A fifth was detected in front of the cricoid cartilage. All five of them were of normal histology. Postoperatively, hypercalcemia persisted. Single Photon Emission Computed Tomography (SPECT) was performed before the second operation and radioguide surgery was carried out by median sternotomy. SPECT showed a parathyroid adenoma in the middle of the anterior mediastinum which was excised (size 1x0.5x0.5 cm) using a gamma probe. In conclusion, SPECT and intraoperative gamma probe application may help to detect the parathyroid adenomas, especially if they are small in size and buried in the adipose tissue. Such localization shortens the duration of the operation and reduces the possibility of complications.