Yazar "Pongswatd, Sawai" seçeneğine göre listele
Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
Yayın Design of PLC-based system for linearity output voltage of AC-DC converter(Elsevier, 2022) Pongswatd, Sawai; Smerpitak, Krit; Asadi, Farzin; Thepmanee, TeerawatThis paper presents the PLC-Based system for controlling the SCR power module which is AC-DC converter proposes to linearity output voltage with trigger signal. The technique converted the trigger signal by arccosine function and analog module in the PLC. Converted signal from PLC system is fed to SCR power module instant the traditional signal. Proposed of this paper describes the PLC hardware configuration, compute/math and trigonometric functions with Studio 5000 software. In addition, the interfacing, parameters configuration, and monitoring are considered for testing. The technique with PLC-based, devices configuration and experimental results have been presented will be useful for electric power supply in the industry with more and more demand to apply the PLC system to develop the traditional industry to semi or automatic control in the industry. (c) 2021 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Yayın Experimental study on energy consumption of temperature control by using on-off intelligent function(ICIC International, 2023) Pongswatd, Sawai; Sopha, Watcharapon; Asadi, Farzin; Smerpitak, Krit; Thepmanee, TeerawatIn order to save electrical energy for on-off temperature control, a useful concept of on-off intelligent function to execute in a programmable logic controller (PLC) is presented. An implementation of PLC-based control system based on electric heating is also described as a case study to demonstrate the performance of the proposed function. IEC 61131-3-based ladder diagrams were created by using Studio 5000 software to run in the PLC modeled CompactLogix L30ER. Compared with the traditional on-off control action, the proposed on-off intelligent function can minimize energy consumption of a heater used in the implemented temperature control by 4.57%-6.65%.Yayın Implementation of control and SCADA system: Case study of Allen Bradley PLC by using WirelessHART to temperature control and device diagnostic(Elsevier, 2022) Thepmanee, Teerawat; Pongswatd, Sawai; Asadi, Farzin; Ukakimaparn, PrapartSystem integration for process automation promoted the technologies that were accessed to functions and data of field device, controller, and SCADA system. In addition, the data from filed devices can apply to solve device diagnostic and preventive maintenance. This paper describes the practical technique to configure and implement of control and SCADA system that focus on integration of field device, PLC controller, and SCADA system. The paper presents case study of Allen-Bradley (AB) PLC by using WirelessHART device to temperature control and device diagnostic through SCADA system. PLC's input/output (I/O) modules are installed that consists of Modbus module, digital I/O module, analog I/O module. In addition, Prosoft configuration builder and Studio 5000 software are new software to build add on Modbus instruction and ladder diagrams, respectively. The experiments perform in case study of temperature control by using Proportional-Integral-Derivative (PID) function in the AB PLC. Wonderware InTouch SCADA software is implemented to monitor the process mimic, trend, and alarm. Moreover, the technique can support the operators and engineers to make decision for process control and devices diagnostic. (c) 2021 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Yayın Remote monitoring and alert system of HV transformer based on FMEA(Elsevier, 2020) Phumpho, Satree; Pongswatd, SawaiThis paper presents a technique to measure and collect maintenance data for remote monitor of high voltage transformer. The technique installs field instruments to measure winding temperature, cooling-oil temperature, inner pressure, electrical power, and so on. IoT2040 is applied for acquisition (DAQ), processing unit and smart gateway. It converts field data into information that enables for real time monitoring and preventive maintenance applications. This technique can transform time-based maintenance to condition-based maintenance. In addition, the proposed script functions are created based on failure modes and effects analysis (FMEA) to identify alarm and alert conditions. Consideration alarm-referenced parameters that are diagnostic, performance/efficiency analysis relate to operation or communication conditions also assign by script functions. The relevant data from IoT2040 can be transmitted to the local computer as well as a remote-mobile devices running the dashboard with Ubidots server. Ubidots server is responsible for HMI and delivering specific alarm and alert services to the user. Users can access for remote monitoring by smart phone, tablet, laptop, and PC. The experiment performs by simulation with 3 phase Oil immersed distribution transformer. Electrical specification is 50 Hz 250 kVA, 22 kV, 400/230 V. The results shown the assigned data, dashboard, and notices message that notices relate the FMEA scripts. The technique provides early warning detection of transformer statuses that make opportunity to take corrective action to prevent failure.